Maintenance plan for central lubrication system (checklist + download)
With a clear maintenance plan, your central lubrication system remains reliable. Use the following Checklist as a basis and adapt it to your system.
Daily
- Check fill level, keep refill points clean
- Visually check for leaks/unusual noises
- Check HMI/PLC messages
Weekly
- Check pressure/stroke values and trends
- Check hoses/lines/fittings for damage
- Check filter display and ventilation
Monthly
- Check dosage quantities randomly
- Adjust intervals if necessary (load/temperature)
- Check lubricant quality (viscosity/contamination).
Download: Maintenance Plan Checklist (PDF) · Advice: Contact
More basics: Central lubrication · Components: Control & monitoring
FAQ
How often do oil/grease change?
According to manufacturer information and trend data; earlier if contaminated.
Which limit values make sense?