Circulating lubrication: design & calculation (flow, cooling, filter)
At the Circulating lubrication The correct design determines stability and service life: flow for the desired one Cooling capacity, matching Filter fineness and reliable Sensors.
1) Derive flow from cooling capacity
Rule of thumb: Thermal output P → mass flow ṁ = P / (c ΔT). With l-density ρ the volume flow results Q = ṁ / ρ.
Example: P = 6 kW, ΔT = 10 K, l c ≈ 1.9 kJ/kgK, ρ ≈ 850 kg/m³ → Q ≈ 22.3 L/min.
2) Filtration & Cleanliness
- Filter fineness suitable for storage/gap sizes (e.g. 10-25 µm)
- Pressure maintaining valve/bypass prevents cavitation risks
- Plan for a clogging indicator and differential pressure sensor
3) Sensors & monitoring
- Pressure (flow/return), temperature (tank/flow), flow per circuit
- Messages/alarms in PLC/HMI with trends
4) Medium & Viscosity
- Viscosity according to operating temperature; sufficient film & pump window
- Monitor oil condition (aging/particles/water)
Checklist
- Define thermal output ΔT → calculate Q
- Set filter fineness & bypass
- Select sensors/signals (OK/Warning/Alarm)
- Determine oil choice & service plan (filter change/oil change).